Its printed title: WO-12 Sterile enough: boiling, pressure cookers, flame, alcohol, carbolic and the sterilisation ladder

This report covers how instruments, dressings, hands and rooms are made safe enough for the work in hand at each rung of the ledger: the ladder of clean, disinfected and sterile, what each method kills, the domestic pressure cooker as autoclave, and the discipline of the sterile field.

Open the PDF 21 pages · 116 KB

Number
394
Letter code
WO-12
Book
HEALING after the FALL
Shelf
Wounds, trauma, surgery and anaesthesia
File
394 WO-12 Sterile enough.pdf
Pages
21
Works cited
1

The rows that check it

  • 12 open
  • 10 marked for safety
  • 01-6 open Safety Cool the cooker by itself, never with water. Lid ajar 30 minutes to dry. A wet pack is not sterile. A dry, intact, closed pack keeps 4 weeks (ICRC rule, Thai data suggest 60 days)
  • 01-8 open Safety No cooker: boiled needle and syringe as a fallback, used the same day (WO-12), against SY-10 H15, which keeps boiling for what touches skin. Marked (the author's decision)
  • 01-9 open Safety Electric multicookers do not sterilise (3 of 4 failed at 300 minutes). Alcohol does not kill spores, deaths followed alcohol soaks (1940). Flame on a needle or lancet tip in …
  • 18-18 open Safety Boil instruments 20 minutes, two reports give 10. Steam 121 °C, 20 minutes unwrapped, 30 wrapped. Boiling leaves spores alive
  • 23-20 open Safety Steam in a stovetop pressure cooker at 121 °C: 20 minutes unwrapped, 30 wrapped
  • 23-23 open Safety Vent steam 10 minutes before closing the valve. Above 1,000 m double the time
  • 23-24 open Safety A sterile pack used within 4 weeks if dry and whole
  • 27-23 open Safety Instruments at 121 °C for 20 minutes, or boiled 20 minutes (10 in two reports, C24)
  • 35-13 open Safety One needle or blade per person. New, or steamed at 121 °C, for each
  • 36-19 open Safety C24, boiling instruments: 20 minutes printed, 10 beside
  • 01-60 open Elista 1988 to 1989, needle changed, syringe reused, children infected with HIV. Roka, Cambodia, 242 infected 2014 to 2015
  • S-2 open ⚠